Unless stated otherwise, traces (both GoLogic and sniffer) are gathered on the very simple 2-mote setup depicted below.

Both motes run the same OpenWSN code, which includes the IEEE802.15.4e reference implementation.

GoLogic traces are gathered using a GoLogic logic analyzer. 6 channels as used per mote. The upper 6 channels are connected to mote 1, the lower 6 channels are connected to mote 2. Mote 1 is the time master of the network; mote 2 synchronizes to that parent.

The four lower channels of each group of 6 (labelled fsmtaskisrradio) correspond to the traces with the same name (and color) define in the state machine.